“METRASTATUM” DEVICE EFFICIENCY AND ULTRASOUND RESEARCH IN DIFFERENTIAL DIAGNOSTICS COWS OF URINE PATHOLOGY

Authors

  • Jakupov I.T. Moldakhmetova G.M., Abultdinova A.B.

Keywords:

postpartum pathologies, clinical methods, ultrasound research, differential diagnosis, chronic catarrhal endometritis, purulent-catarrhal endometritis, involution of the uterus, lochia, “Metrastatum” device.

Abstract

Disease prevalence of genital organs in Holstein-Friesian cows with various forms and currents is 51.3%. Which 4.5% are acute and 55.6% are chronic forms of endometritis. In red steppe breed cows found 53.8% of pathologies. From which acute fibrinous endometritis is 39.2% and chronic catarrhal endometritis 35.7%. These pathologies diagnosing with clinical, instrumental and biophysical methods, 10-30 days after calving, efficiency of the Metrastatum device is 8.7% - 40% higher than when using the ultrasound and rectal method of research, and by 31- 60, 61 and more days after calving, effectiveness of the ultrasound method was 7.1% -14% higher compared of instrumental method.

Published

2021-05-28